Concrete is weak in tension, therefore BRC Wire Mesh with high yield strength cold-drawn wires of small size and close spacing reinforcement must be used to provide well distributed tensile reinforcement that is entirely adequate.
Square Mesh | ||||||||
Ref. No. |
B.S.4483 or MS 145 Ref. No. |
Longitudinal Wires | Cross Wires | Cross-Sectional Area | Mass Per Unit Area kg/m2 | |||
Size (mm) | Spacing (mm) | Size (mm) | Spacing (mm) | Long'L (mm2/ m) | Cross (mm2/m) | |||
A12 | A565 | 12 | 200 | 12 | 200 | 565 | 565 | 8.88 |
A10 | A393 | 10 | 200 | 10 | 200 | 393 | 393 | 6.16 |
A9 | A318 | 9 | 200 | 9 | 200 | 318 | 318 | 4.99 |
A8 | A252 | 8 | 200 | 8 | 200 | 252 | 252 | 3.95 |
A7 | A193 | 7 | 200 | 7 | 200 | 193 | 193 | 3.02 |
A6.5 | A166 | 6.5 | 200 | 6.5 | 200 | 166 | 166 | 2.61 |
A6 | A142 | 6 | 200 | 6 | 200 | 142 | 142 | 2.22 |
A5 | A98 | 5 | 200 | 5 | 200 | 98 | 98 | 1.54 |
A4 | A63 | 4 | 200 | 4 | 200 | 63 | 63 | 0.99 |
Rectangular Mesh | ||||||||
Ref. No. |
B.S.4483 or MS 145 Ref. No. |
Longitudinal Wires | Cross Wires | Cross-Sectional Area | Mass Per Unit Area kg/m2 | |||
Size (mm) | Spacing (mm) | Size (mm) | Spacing (mm) | Long'L (mm2/ m) | Cross (mm2/m) | |||
B12 | B1131 | 12 | 100 | 8 | 200 | 1131 | 252 | 10.90 |
B10 | B785 | 10 | 100 | 8 | 200 | 785 | 252 | 8.14 |
B9 | B636 | 9 | 100 | 8 | 200 | 636 | 252 | 6.97 |
B8 | B503 | 8 | 100 | 8 | 200 | 503 | 252 | 5.93 |
B7 | B385 | 7 | 100 | 7 | 200 | 385 | 193 | 4.53 |
B6 | B283 | 6 | 100 | 7 | 200 | 283 | 193 | 3.73 |
B5 | B196 | 5 | 100 | 7 | 200 | 196 | 193 | 3.05 |
Long Rectangular Mesh | ||||||||
Ref. No. |
B.S.4483 or MS 145 Ref. No. |
Longitudinal Wires | Cross Wires | Cross-Sectional Area | Mass Per Unit Area kg/m2 | |||
Size (mm) | Spacing (mm) | Size (mm) | Spacing (mm) | Long'L (mm2/ m) | Cross (mm2/m) | |||
C10 | C785 | 10 | 100 | 6 | 400 | 785 | 71 | 6.72 |
C9 | C636 | 9 | 100 | 6 | 400 | 636 | 71 | 5.55 |
C8 | C503 | 8 | 100 | 5 | 400 | 503 | 49 | 4.34 |
C7 | C385 | 7 | 100 | 5 | 400 | 385 | 49 | 3.41 |
C6 | C283 | 6 | 100 | 5 | 400 | 283 | 49 | 2.61 |
C5 | C196 | 5 | 100 | 5 | 400 | 196 | 49 | 1.93 |
Rectangular Mesh | ||||||||
Ref. No. |
B.S.4483 or MS 145 Ref. No. |
Longitudinal Wires | Cross Wires | Cross-Sectional Area | Mass Per Unit Area kg/m2 | |||
Size (mm) | Spacing (mm) | Size (mm) | Spacing (mm) | Long'L (mm2/ m) | Cross (mm2/m) | |||
DA12 | DA1131 | 12 | 100 | 12 | 100 | 1131 | 1131 | 17.75 |
DA10 | DA785 | 10 | 100 | 10 | 100 | 785 | 785 | 12.32 |
DA9 | DA636 | 9 | 100 | 9 | 100 | 636 | 636 | 9.98 |
DA8 | DA503 | 8 | 100 | 8 | 100 | 503 | 503 | 7.90 |
DA7 | DA385 | 7 | 100 | 7 | 100 | 385 | 385 | 6.04 |
DA6 | DA283 | 6 | 100 | 6 | 100 | 283 | 283 | 4.44 |
DA5 | DA196 | 5 | 100 | 5 | 100 | 196 | 196 | 3.08 |
DA4 | DA126 | 4 | 100 | 4 | 100 | 126 | 126 | 1.97 |